FuelCell Energy & Toyota Complete World’s First Tri-Gen Production System — Hydrogen, Power & Heat

Alexandra Blake
podľa 
Alexandra Blake
3 minúty čítania
Blog
február 13, 2026

FuelCell Energy & Toyota Complete World's First Tri-Gen Production System — Hydrogen, Power & Heat

Prioritize facilities with steady thermal loads and vehicle fleets: target sites that consume more than 1 MW electrical or have fleets that refuel at a single stanica. Begin a pilot within 6–12 months, validate integration with the local užitočnosť, then plan expansion across campuses over 24–36 months. These steps help operations reduce external purchase exposure and streamline maintenance for different models of backup power and hybrids.

Specify performance targets up front: require continuous baseload power delivery, defined hydrogen output for vehicle refueling, and captured heat for onsite process use. Tie supplier contracts to uptime guarantees and measurable reductions in harmful emissions so the facility shows real results annually. Use fleet telemetry and building meters to report energy and hydrogen volumes, and to resolve any interconnection problém within 30 days.

Choose modular fuelcell architectures that match manufacturing plans a products roadmaps: modular stacks simplify add-on capacity for amerika-based production sites and support different hydrogen purity outputs for station dispensing. Negotiate options for spare modules, training, and remote diagnostics to reduce downtime and speed troubleshooting.

Factor total cost of ownership in procurement: compare utility tariffs, station refueling economics and avoided diesel standby costs over a 5–8 year horizon. Combine capital incentives, long-term service agreements and predictable purchase commitments for hydrogen to improve returns. This approach makes the world-class FuelCell Energy & Toyota tri-gen model practical and scalable, helping corporate sustainability goals while keeping operations resilient.

Detailed operational and project-analysis checklist for the Long Beach Tri‑Gen deployment

Assign an operations lead within 14 days and set KPIs: availability ≥ 92% monthly, electrical output target approximately 2–3 MW, hydrogen purity ≥ 99.97% (5N) for vehicle fueling, thermal recovery target 1.5–2 MWth; log KPI variances daily and escalate unresolved issues within 48 hours.

Confirm project financing structure and schedule: itemize capex and contingency, expect cost ranges commonly between $10M–$30M depending on scale and interconnection; secure financing commitments that cover at least 18 months of operation and one full stack replacement to avoid cash-flow interruptions.

Validate utility interconnection milestones with the local utility and wastewater partner: obtain point-of-interconnection approval, short-circuit and protection studies, and physical protection for transformers; reserve capacity for peak export of approximately 2–3 MW and negotiate firm vs. interruptible tariffs to optimize revenue.

Complete permitting and safety reviews in the first 90 days: HAZOP, seismic anchor review for high-pressure hydrogen storage, and fire department sign-off for hydrogen dispensers; ensure documentation shows separation distances and ventilation rates for areas where hydrogen will be stored, filled, or pumped to dispensers.

Benchmark the fuel type and feedstock: confirm the plant will be powered by biogas from the wastewater area, sample contaminants quarterly, and install pre-treatment to reduce siloxanes and hydrogen sulfide; document expected methane slip and how the system emits net greenhouse gases relative to the regional grid.

Establish a preventive maintenance plan tied to operating hours: schedule stack inspections every 8,000 hours, electrolyte stack replacement approximately every 40,000 hours unless companys warranty specifies otherwise, and rapid-response spares holding for common failure modes to limit downtime to under 72 hours per event.

Define hydrogen delivery and fueling operations: size on-site storage for 1–3 days of output, confirm compressor duty cycles for pumped hydrogen to dispensers, validate dispenser flow rates to meet mirai refueling times (target <5 minutes for 5 kg), and implement dispenser purge and leak-detection routines.

Set commercial and revenue protocols: lock power purchase agreement terms with price escalators, document hydrogen sales pricing and minimum take-or-pay, and identify credit stacking (RINs, LCFS or equivalent) applicable in developing or brazilian markets if replication is planned; assign revenue reporting to finance weekly.

Integrate controls and data telemetry: implement SCADA with redundant links, stream stack voltage, cell temperatures, hydrogen purity and flow, and grid export in 1-minute resolution; enable remote ramp control for grid events and require two-factor authentication for control changes to reduce cybersecurity exposure.

Define staffing, training, and emergency response: staff shifts so people overlap for 2 hours during turnover, train teams on hydrogen-specific procedures and Mirai fueling differences compared to compressed natural gas, and run quarterly drills with local emergency responders where the plant and utility play defined roles.

Draft contracts and partner responsibilities: issue clear scopes to each partner (operator, equipment supplier, utility, offtaker) and require performance targets and liquidated damages for missed KPIs; include acceptance test protocols (72-hour continuous run, hydrogen purity, electrical output) and clause allowing announcement of commissioning only after acceptance sign-off.

Monitor lifecycle and end-of-life planning: record degradation rates, estimate replacement cost per stack and balance-of-plant components, create an end-of-life recycling plan for catalyst and membranes, and budget decommissioning costs to prevent unexpected liabilities that otherwise increase total cost of ownership.

On‑site hydrogen production: selected reforming/fuel‑cell pathway, required purity, continuous flow rates and storage sizing

Recommendation: Install an autothermal reformer (ATR) with staged desulfurization and a membrane polish unit to supply a PEM fuel‑cell stack, design storage for a 30‑minute operational buffer plus scalable daily reserves and size generation for continuous baseline loads with modular add‑ons for station peak support.

Selected pathway: use ATR (or ATR + PSA/membrane) for natural gas or renewable gas; choose catalytic partial oxidation or steam methane reforming (SMR) only where waste heat recovery is available. For nafta alebo biomass feedstocks add a heavy‑hydrocarbon cracker and multi‑stage desulfurizer (<0.1 ppm S) upstream of reforming. For compact, highly versatile installations consider internal reforming with SOFC where the electrochemical cell tolerates CO, but select ATR+membrane/PEM where onsite-generated hydrogen must meet strict purity for sensitive loads.

Purity requirements (design targets): for PEM fuel cells specify H2 ≥ 99.999% (5.0), CO 0.1 ppm, CO2 5–10 ppm, H2O dew point ‑40 °C. For low‑temperature PEM stacks keep hydrocarbons and sulfur below detection; use palladium membranes or electric swing adsorption (ESA) polishers if PSA only delivers ~99.9%. For high‑temperature SOFC accept reformate with H2 ≥ 90–95% and CO up to a few percent, but maintain sulfur 0.1 ppm and control particulate load.

Continuous flow rates and quick sizing rules: use LHV = 33.3 kWh/kg H2. Estimate hydrogen consumption as H2_kg/hr = Electric_kW ÷ (LHV_kWh/kg × FuelCell_efficiency). Examples at assumed electrical efficiency 50%: 1 MW elec → 1,000 kW ÷ (33.3×0.5) ≈ 60 kg/h (~1.44 tons/day); 250 kW → ≈ 15 kg/h (~360 kg/day); 100 kW → ≈ 6 kg/h (~144 kg/day). Size reformer steady‑state capacity at +20–30% margin for degradation and maintenance, and include a fast ramp capability of 0–100% in 5–10 minutes for grid‑responsive programs.

Storage sizing and formats: specify two tiers – a short buffer (15–60 minutes) for transient support and a daily reserve (4–24 hours) for resilience or islanded operation. Buffer_mass_kg = Flow_kg/hr × Buffer_hours. For a 1 MW example: 60 kg/h × 0.5 h = 30 kg buffer; daily reserve (24 h) = 1,440 kg (~1.44 tons). Compressed options: at 700 bar ≈ 40 kg/m³, 1,440 kg occupies ≈ 36 m³; at 350 bar ≈ 23 kg/m³, ≈ 63 m³. Cryogenic liquid H2 yields smaller volume but needs boil‑off management and is less cenovo dostupné for compact factory use. Metal hydrides or chemical carriers provide compact footprints where safety and space are premium, but verify manufacturer cycling life and thermal management.

Integration and operational strategy: tie the reformer‑fuel‑cell system into onsite electric and thermal loads so waste heat from reforming and the fuel cell supplies HVAC or process heat in factories; use a controller that supports grid interactions and a diesel genset as emergency backup for facilities without reliable grid. For customer programs and manufacturer plans, phase capacity in modular units so the system supports initial station power needs and scales to multi‑ton outputs as demand grows. Document feedstock source (natural gas, biomethane, biomass gasification streams) and trail sample logs for molecules that affect catalyst life; it is important that sulfur, chlorides and heavy aromatics stay below design thresholds.

Commercial considerations: align capital and O&M in a total cost strategy that makes onsite hydrogen cenovo dostupné a vysoko reliable for customers across America – include warranties, a service program, and spare modules sized to handle peak recovery. Position the plant as a world‑class example of versatility: modular reformer + membrane polish + fuel cell with storage, designed to supply power, heat and H2 fuel to stations, factories and field programs while minimizing diesel reliance and maximizing onsite‑generated clean molecules.

Electric generation output and grid integration: nameplate capacity, interconnection steps, export limits and meter/controller requirements

Limit initial export to 20–30% of nameplate capacity and phase increases only after islanding, protection and telemetry tests pass; this reduces queue delay, cost spikes and compliance risk.

  • Nameplate capacity: choose exact rated MW/kW based on steady CHP output and grid needs.

    • For commercial facilities: 250 kW–2 MW fuelcell systems typically cover baseload and heat loads while remaining manageable for interconnection.

    • For campus or industrial: 2–10 MW nameplate supports resiliency and export revenue while requiring substation upgrades.

    • Estimate capital investment at roughly $1–3 million per MW for fuelcell-based projects; site-specific conditioning, permitting and gas hookups can push totals higher.

  • Interconnection steps (sequenced, with expected durations and costs):

    1. Pre-application screening (7–30 days): verify hosting capacity and preliminary export allowance; cost: nominal administrative fee.

    2. Feasibility study (30–60 days): utility evaluates short-circuit, protection and thermal limits; typical cost $10k–$50k.

    3. System impact study (60–120 days): models dynamic behavior, anti-islanding and voltage/frequency response; expect $25k–$150k depending on scope.

    4. Facilities study (60–180 days): defines physical upgrades, relay settings and metering points; costs vary from $50k to several million if substation work required.

    5. Generator interconnection agreement (GIA) and construction (3–12+ months): sign, fund upgrades, install equipment, and schedule witness testing.

    6. Commissioning and performance tests: staged ramp to full export after protective settings and telemetry pass; with fuelcell systems, test sequences emphasize continuous operation and rapid ramp testing.

  • Export limits and practical sizing guidance:

    • Set initial export limit to 20–30% of nameplate to limit protection coordination work and speed approval; increase to 50–100% only after successful dynamic testing and possible substation upgrades.

    • If the site plans to export for pricing arbitrage or capacity markets, size exportable inverter or tie capacity separately from CHP thermal sizing to avoid overbuilding fuel delivery and motor loads.

    • For californias interconnection queues, expect stricter anti-islanding and telemetry requirements and sometimes tighter export caps for distribution-connected plants under 5 MW.

    • Example: a 1 MW fuelcell nameplate with 250 kW export limit provides protected local resiliency while enabling limited market participation.

  • Metering, controller and protection requirements (must-have list):

    • Revenue-grade bi-directional meter at PCC (ANSI C12 / IEC equivalent) with independent CT/PT sets, calibrated and sealed for export accounting.

    • Fast-acting protective relays and transfer trip compliant with IEEE 1547 and UL 1741 SA; anti-islanding must be certified and tested on-site.

    • Plant controller/RTU with SCADA integration, 4–20 mA or IEC 61850 telemetry for real-time visibility and remote dispatch; include logging for frequency, voltage, and ramp events.

    • Voltage regulation and power factor controls capable of +/-5% setpoints and reactive support per utility specifications; include ramp-rate limiting to match distribution constraints.

    • Automatic resumption sequence and black-start logic if facility replaces diesel resumption scenarios; document protected sequences for safety and grid stability.

    • Fuel management and transient controls when utilizing natural gas or hydrogen blends: sensors for flow, pressure, and molecule quality (hydrogen mol%), interlocked with generation control to prevent unsafe operation.

  • Operational recommendations and procurement checklist:

    • Purchase controllers and relays with firmware supporting remote upgrades and market signaling; purchasing lower-cost gear that later requires replacement increases lifecycle cost.

    • Specify fuelcell and fuelcells interfaces for continuous operation and CHP sequencing to achieve efficient heat recovery and emission reduction compared to diesel gensets.

    • Contractual language should protect the facility against unexpected interconnection upgrade pricing; use fixed-price milestones where possible for major substation work.

    • Budget for studies and potential substation work: plan $100k–$2 million contingency depending on distance to the nearest suitable transformer.

    • Track project pace with milestone-based payments and test windows; thats how teams keep schedule and cashflow aligned.

  • Performance and market integration tips:

    • Use coordinated dispatch between the fuelcell system and facility motor loads to minimize export during peak distribution stress while maximizing on-site consumption and affordable energy use.

    • Register telemetry for capacity or ancillary markets early; delays in telemetry approvals often block market participation despite technical readiness.

    • Document scenarios where resumption of backup diesel wouldnt be required thanks to fuelcell CHP continuous heat and power; this supports emissions crediting and lowers lifecycle cost.

    • For multi-project portfolios, pool exported capacity between facilities only after confirming protected control schemes and aggregate protection studies; aggregation can boost revenue but raises complexity.

These recommendations reflect strategic trade-offs between upfront investment, interconnection time and long-term operational pricing; applying them helps projects achieve predictable permitting, protected revenue streams and efficient operation while supplying reliable power and heat to the facility and the globe.

Heat recovery and utilization: recovered thermal profiles, distribution loop design, and on‑site end‑use matching

Heat recovery and utilization: recovered thermal profiles, distribution loop design, and on‑site end‑use matching

Set the primary supply to 90°C with a design ΔT of 10–15°C and target 80–90% thermal recovery from the fuelcell exhaust and coolant circuits. For a 2 MW electrical module that produces 4.5 MWth of recoverable heat, this yields a required primary flow of roughly 52–78 L/min per MWth (water, 90→75°C) or 260–390 L/min for the whole system; size pumps for 0.6–1.0 m³/h per kW of thermal to maintain the ΔT and allow turndown without short‑cycling.

Use a pumped, dual-loop arrangement: a high‑temperature primary loop (90/75°C) captures heat directly from the cell stacks and coolant headers, and a low‑temperature secondary loop (70/45°C) supplies space heating and process loads. Install a 1,000–2,000 L buffer tank per MWth to stabilize transient loads and permit stable electricity production. Fit plate heat exchangers (PHE) sized for 25–30 kW/m² heat flux and include a 3‑valve bypass plus a VFD on the primary pump to keep ΔT within range as loads change.

Match recovered thermal profiles to on‑site end uses by mapping load temperature vs. hourly demand over a 12‑month period at 15‑minute resolution. Allocate heat by priority: (1) fueling station pre‑heating and hydrogen compression (requires 80–95°C), (2) absorption chiller drive for cooling (85–95°C for single‑effect), (3) domestic hot water (60–65°C), (4) space heating and cargo‑handling area tempering (45–60°C). Fit thermostatic mixing valves and dedicated PHEs so high‑grade heat that is produced feeds high‑temperature demands first; cascade remaining heat downward to lower‑grade loops to avoid wasted exergy.

Implement control logic that pumps heat where and when needed: use heat meters on each branch, prioritize high‑value loads by PID setpoints, and allow manual override for maintenance. For the project’s first‑of‑its‑kind tri‑gen site, operators told project people to set the pump speed limit to retain 25% buffer head at minimum load and to enable a 5–10 minute minimum runtime to reduce cycling on arms and valves. Log metered thermal energy (kWhth), electricity produced, and hours at each temperature band to quantify recovered vs. wasted heat.

Design piping and insulation for minimal losses: use pre‑insulated carbon steel or stainless lines sized to keep velocity 0.6–1.2 m/s, keep round‑trip losses under 2°C across the site area, and use closed‑cell foam insulation to achieve U‑values below 0.5 W/m²·K. Specify pumps with corrosion‑resistant materials for pumped glycol mixes when freeze protection is needed for outdoor trail runs or peripheral fueling equipment.

Optimize economics by pairing heat sinks and flexibility: combine local district loads (automaker test cells, cargo‑handling docks) with site processes that accept variable temperature – hydrogen fueling skids and absorption chillers ramp with 5–15% efficiency variation but accept lower‑grade heat. Track payback using thermal offset value ($/kWhth) versus electricity produced; highlight that innovation in control and distribution represents a world-class example where fuelcell systems bring zero‑emission electricity and usable heat to different on‑site demands and common industrial models.

Plant controls, safety systems and emergency response: H2 leak detection, ventilation, shutdown sequence and training deliverables

Install a layered H2 detection and automated shutdown chain that trips at 10% LEL alarm, isolates the source at 20% LEL and depressurizes the affected zone within 120 seconds.

Deploy fixed catalytic bead or electrochemical H2 sensors at ceiling level and inside ducts; place portable sensors for cargo-handling and maintenance tasks. Space ceiling sensors every 10–15 m line-of-sight in open rooms and every 5–8 m in compartmented areas; locate one detector per 100–200 m3 in low-height enclosures. Use redundant 2oo3 voting for each safety input and test detectors monthly with a bump test and calibrate every six months. Replace catalytic sensors every 24 months and electrochemical sensors every 36 months, and log calibration results into the plant historian.

Design ventilation to bias flow upward and out: supply air at low level and extract at high level to exploit hydrogen buoyancy. Size emergency extraction to achieve a purge rate that reduces a 2% H2 concentration to below 1% within 5 minutes; as a rule of thumb, provide 8–12 air changes per hour (ACH) in occupied enclosed rooms and 20+ ACH for compressor rooms or areas where hydrogen is generated or pumped. Locate vents and stacks upwind of pedestrian zones and fuelcell modules, and fit flame arrestors and atmospheric dispersion modeling outputs for exact stack heights.

Sequence controls to act without operator input: 1) local detector alarm (visual + 85 dB audible) and notify control room within 1 s; 2) automatically open high-capacity exhaust and start makeup fans within 2–5 s; 3) close H2 isolation valves (motorized, spring-return) and stop pumps or compressors that pumped biogas or H2 into the affected train within 5–10 s; 4) trip fuelcell power electronics and disconnect electricity export breakers within 10–15 s; 5) place the module in a monitored safe state and maintain telemetry back to the SCADA for 30 minutes of elevated logging. Implement a manual override that requires two-person authorization and logs both IDs.

Integrate safety PLC logic, skid-level controllers and the facility SCADA so events generated by any manufacturer equipment propagate into the same alarm and logging stream. Time-stamp data at 1 Hz for the first 30 minutes after an event and aggregate to 1-minute intervals thereafter; retain detailed logs for five years. Ensure control hardware uses SIL-2 certified modules for H2 isolation and that the HMI shows clear module states, purge progress and exact valve positions.

Umiestnenie Alarm level (% LEL) Automated action Doba odozvy
Ceiling – production hall 10% Local alarm, start exhaust, notify SCADA <5 s
Compressor room 8% Start high-rate extraction, close inlet valve, trip compressor <3 s
Fuelcell module room 10% Isolate module, stop feed pumps, disconnect export breaker <15 s
Venting ducts / stack 20% Open vent reliefs, activate dispersion fans <10 s

Train operations staff on a curriculum of: H2 properties and ignition limits, sensor placement and failure modes, exact shutdown sequence walkthroughs on the real SCADA, lockout-tagout for fuelcell skids, and cargo-handling procedures for cylinders and trailers. Deliverables include a 4-hour classroom module, two 2-hour hands-on sessions per year, electronic quick-reference cards, and competency assessments with a passing score ≥90%. Run tabletop exercises quarterly and full-scale emergency drills annually with participation from local emergency services.

Document emergency contacts for manufacturers, maintenance contractors and the local fire brigade; store contact lists both in control room and offline. Provide spare parts kits for critical valves, sensor heads and actuators on-site to reduce mean time to repair. Modernize control firmware on a planned two-year cadence and validate changes in a staging environment before pushing back to production.

Adopt clear handover rules between production and maintenance: tag the same permits for work on biogas lines that feed the fuelcell system, ensure pumps show zero pressure and are electrically isolated, and require a supervisor sign-off before re-pressurizing. Match H2 venting paths to prevailing wind data so released hydrogen disperses away from public access and neighboring equipment.

Measure performance metrics: mean detection-to-isolation time ≤12 s, purge-to-clear (below 1% H2) ≤300 s, monthly detector uptime ≥99.5%, and drill pass rate ≥95%. Use these KPIs to justify investments in additional sensors, upgraded equipment or reconstruction of constrained spaces to help achieve zero unplanned releases and protect electricity production continuity.

Include post-event deliverables: a root-cause report within 72 hours, annotated P&ID updates, remediation action list with owner and exact completion dates, and a follow-up drill that verifies implemented fixes. This approach helps operators, manufacturer service teams and emergency responders align on options to reduce risk and restore the facility back to safe production.

Permitting and utility coordination: specific regulatory objections from Southern California Edison and actionable steps to address them

Permitting and utility coordination: specific regulatory objections from Southern California Edison and actionable steps to address them

Recommendation: File a coordinated permit and interconnection packet with SCE and CPUC within 30 days that includes a Feasibility Study request, a complete one-line electrical diagram showing fuelcell and biogas interfaces, a HAZOP for hydrogen systems, and a phased commercial operation plan that specifies the hydrogen production rate (example: system produces 3.5 tons H2/year and displaces ~60,000 gallons diesel-equivalent annually).

SCE objection: interconnection queue delays and incomplete study data. Action: submit an executable plan that bundles a Pre-Application Study, Feasibility Study (4–8 weeks), System Impact Study (12–20 weeks) and Facilities Study (12–24 weeks), plus time-stamped SCADA telemetry requirements. Provide measured load profiles, hourly generation bids, steady-state and dynamic data, and protection settings. Commit to a 4-second SCADA update rate and provide inverter/DG controls that supply up to 2–5 MVAr for voltage support during contingencies.

SCE objection: distribution capacity and cost allocation for upgrades. Action: present a multi-strategy mitigation package that includes (1) on-site reactive compensation, (2) phased energys injection during off-peak to reduce peak demand by 15–25%, and (3) cost-sharing proposals with investor-owned utility oversight. Include modeled load flow runs showing the project reduces feeder overload hours by X per year (insert modeled hours) and quantify tariff-sensitive metrics that lower forecasted standby/backup charges.

SCE objection: rate and tariff classification (retail vs. wholesale). Action: file a joint CPUC-SCE tariff request that documents grid benefit: avoided outages, reduced electricity price volatility, and congestion relief. Provide a business-case annex for investor-owned tariff adjustments, showing present value of avoided network costs and a benefit allocation that represents public and private gains. Include a simple amortization schedule for incremental equipment costs tied to utility-requested upgrades.

SCE objection: safety and siting risks for hydrogen production adjacent to distribution assets. Action: submit NFPA 2 and ASME-compliant designs, a full HAZOP, a dispersion modeling report for worst-case releases (molecules per cubic meter), and third-party verification. Coordinate with local Fire Department, South Coast AQMD for biogas permits, and the county building official; deliver an Emergency Response Plan and joint drills schedule with SCE operations to avoid damaged equipment and unsafe operation during transient events.

SCE objection: protection, islanding, and power quality concerns. Action: provide relay settings, anti-islanding proof tests, harmonic studies, and real-time ride-through performance data. Propose an adaptive protection scheme that SCE can validate in a staged commissioning window and commit to remote access for relay logs during commissioning. Offer a firmware freeze period post-commissioning to stabilize operation during the first 12 months.

SCE objection: uncertainty over fuel supply and environmental impacts for biogas-to-hydrogen pathways. Action: supply long-term fuel supply agreements, chain-of-custody documentation for biogas, and lifecycle GHG calculations that show CO2-equivalent reductions in tons/year. Provide contingency gas supply options and a cargo-handling layout for delivered feedstocks; include equipment redundancy and spare-parts inventory levels that support uninterrupted operation and expansion.

SCE objection: perceived lack of community or regional benefit. Action: prepare a benefits dossier that quantifies local electricity price relief, job creation, and support for electrification and regional hydrogen supply. State projected metrics: number of jobs during construction and operation, annual tons of hydrogen produced, gallons-equivalent fuel displaced, and the percentage reduction in local NOx/PM from replacing diesel cargo-handling equipment. Include an outreach timeline and minutes from stakeholder meetings.

Operational handoffs and contractual language: include SCE-reviewed acceptance tests, an agreed commissioning checklist, and maintenance windows. Insert clear penalties and incentives tied to milestone dates. Use a multi-year O&M escrow to protect investor-owned utility interests and to ensure fast remedy if equipment is damaged during joint activities.

Documentation and approvals checklist (deliverables within 30–180 days): executed interconnection application, feasibility and impact study deliverables, SCADA spec, HAZOP report, dispersion modeling, AQMD/air permits for biogas processing, building/fire approvals, tariff negotiation packet, and a public benefit statement that represents project value to america energy transition. Maintain a single point of contact and weekly coordination calls until commercial operation date.

Final note: maintain transparency in cost estimates, include strong contingency reserves, and present a phased commissioning timeline that supports gradual energys injection while SCE validates protections and power quality. That combination reduces objection windows, accelerates permitting approval, and maximizes the production benefit to investors and the community – feliz stakeholders and smoother expansion while supplying resilient power, heat and hydrogen.

Commercial framework to restart the project: hydrogen/power/heat offtake contracts, revenue stack, financing milestones and timeline to construction resumption

Execute a phased commercial restart anchored by secured offtake contracts: sign a 10–15 year hydrogen offtake (H2) with minimum take-or-pay of 60 percent of nameplate, a 7–12 year power purchase agreement (PPA) at fixed + index escalation, and multi-year heat supply agreements with ports and nearby factories for refuse heat and steam.

Structure the revenue stack so hydrogen sales represent ~45 percent of operating revenue, power sales ~35 percent, and heat/steam ~20 percent. Include ancillary revenues from grid services (frequency response, capacity) and fuel credit stacking for biomethane blends. Require offtakers to accept onsite-generated hydrogen for a local station and industrial processes; index hydrogen pricing to an agreed energy basket and CPI with annual floor/ceiling to limit market exposure.

Lock in a tiered offtake portfolio that mixes an anchor industrial buyer (Toyota or a Brazilian chemical producer), a regional utility PPA, and municipal heat customers. Use a world-class fuelcell manufacturing partner to guarantee performance; put performance guarantees and liquidated damages in supply contracts so the manufacturer stands behind production output. Engage named stakeholders such as Laffoon and representative ports to finalize term sheets within 90 days.

Target a restart capex of $200–220 million. Finance with 30 percent equity (~$60–66M) committed at term-sheet, 55 percent debt (~$110–121M) placed at FID, and 15 percent grants/incentives (~$30–33M) from federal, state and Californias-level programs. Milestones: equity close within 3 months, debt term sheet within 6 months, grant award notifications within 9–12 months, FID at 12 months, and construction restart within 14–16 months.

Define contractual milestones tied to financing tranches: a first tranche (10 percent capex) releases on equity close and signing of anchor H2 + PPA; a second tranche (40 percent) releases on debt commitment and grant term-sheets; final tranche (50 percent) releases at FID and issuance of construction permits. Require lender conditions that include offtake coverage ratios, environmental permits, and proof of fuel supply flexibility to accept biomethane or natural gas blend if biomethane supply would be limited.

Mitigate commercial and technical risk by building fuel flexibility into offtakes (ability to accept produced hydrogen and biomethane blends), requiring routine performance reporting, and modeling an emissions reduction case that quantifies harmful emissions avoided and benefits produced for community reporting. Timeline summary: 0–3 months finalize anchor contracts and equity; 3–6 months secure utility term-sheets and permit applications; 6–12 months close debt and incentives; month 12 FID; month 14–16 construction mobilization; month 30–36 commissioning and full production. These concrete steps align investment, manufacturing, operations and community benefits so the project can restart together with clear financing triggers and a predictable revenue trail for investors and off-takers.